Olympus EPOCH 650 Ultrasonic Flaw Detector
Features:
– Designed to meet the requirements of EN12668-1
– PerfectSquareTM tunable square wave pulser
– Full screen A-scan mode
– Digital high dynamic range receiver
– Thirty digital filters for enhanced signal-to-noise ratio
– 2 kHz PRF for rapid scanning
– Knob or navigation pad adjustment configurations
– Large, full VGA sunlight readable display
– 15+ hours of battery life
– Standard dynamic DAC/TCG and onboard DGS/AVG
– Multiple on-board report formats
– MicroSD memory card for data transfers
– Optional Corrosion Module software with Encoded B-scan
– USB On-The-Go (OTG) for PC communication
– Alarm and VGA outputs
– Optional analog output
Portable, Rugged, and Ergonomic
Physical Features
The EPOCH 650 is a lightweight, portable flaw detector built to be rugged and flexible for nearly any inspection. Some key physical features include:
– Large, full VGA resolution transflective display for vivid clarity in any indoor lighting and direct sunlight conditions
– Rubber overmolded bumpers on all four corners for shock absorption and anti-marring considerations
– Four-point harness connection for chest straps
– No tools access to battery compartment and side I/O door
– Continuous position stand with right angle crook for improved stability from 0 to 180 degrees
– Gasketed side door for USB OTG connection and removable memory
– Standard internal, rechargeable lithium-ion battery
– Lightweight, ergonomic design for increased portability and ease of use
Specifications:
USB On-The-Go (OTG) |
Yes |
VGA output standard |
1 analog output (optional), Selectable 1 V/10 V Full Scale, 4mA max |
3 alarm outputs, 5 V TTL, 10 mA |
Trigger input, 5V TTL, Trigger output, 5V TTL, 10 mA max |
1-axis encoder line (quadrature – Corrosion Module mode only) |
Designed to meet the standards of the Ingress Protection (IP) rating number IP67 (navigation pad version) or IP66 (knob version) per IEC 60529-2004 (Degrees of Protection provided by enclosures IP Code). The product design was confirmed to meet the IP rating by means of Olympus internal design verification test process that occurs prior to the release of the product to production. |
Safe operation as defined by Class I, Division 2, Group D, as defined in the National Fire Protection Association Code (NFPA 70), Article 500, and tested using MIL-STD-810F, Method 511.4, Procedure I. |
MIL-STD-810F, Method 516.5 Procedure I, 6 cycles each axis, 15g, 11 ms half sine. |
MIL-STD-810F, Method 514.5, Procedure I, Annex C, Figure 6, general exposure: 1 hour each axis |
10 C to 50 C (14 F to 122 F) |
0 C to 50 C (32 F to 122 F) |
236 mm x 167 mm x 70 mm (9.3 in. x 6.57 in. x 2.76 in.) |
1.6 kg (3.5 lb), including lithium-ion battery |
English, International, Japanese, Chinese |
English, Spanish, French, German, Japanese, Chinese, Portuguese, Russian |
BNC or Number 1 LEMO |
100,000 IDs onboard, removable 2 GB MicroSD card (standard) |
Single lithium-ion rechargeable standard |
15 h to 16 h (lithium-ion) |
AC Mains: 100 VAC to 120 VAC, 200 VAC to 240 VAC, 50 HZ to 60 Hz |
Full VGA (640 x 480 pixels) transflective color LCD, 60 Hz update rate |
117 mm x 89 mm, 146 mm (4.62 in. x 3.49 in., 5.76 in.) |
Tunable Square Wave |
10 Hz to 2000 Hz in 10 Hz increments |
100 V, 200 V, 300 V or 400 V |
Adjustable from 25 ns to 5,000 ns (0.1 MHz) with PerfectSquare technology |
50, 100, 200, 400 |
0 to 110 dB |
20 V p-p |
400 ±, 5% |
0.2 MHz to 26.5 MHz at -3 dB |
Thirty digital filter sets standard Seven EN12668-1:2010 compliant filters (0.2-10 MHz, 2.0-21.5 MHz, 8.0-26.5 MHz, 0.5-4 MHz, 0.2-1.2 MHz, 1.5-8.5 MHz, 5-15 MHz) |
Full-wave, Positive Half-wave, Negative Half-wave, RF |
Horizontal: ±, 0.5% FSW |
0.25% FSH, amplifier accuracy ±, 1dB |
0 to 80% FSH with Visual Warning |
0 to 110% full screen height with 0.25% resolution |
Equivalent to PRF in all modes |
Velocity, Zero Offset Straight Beam (First Backwall or Echo-to-Echo) Angle Beam (Soundpath or Depth) |
Pulse Echo, Dual, or Through Transmission |
Millimeters, inches, or microseconds |
3.36 mm to 13,388 mm (0.132 in. to 527.10 in.) @ 5,900 m/s (0.2320 in./&mu,) |
635 m/s to 15240 m/s (0.0250 in./s to 0.6000 in./s) |
0 s to 750 s |
-59 mm to 13,401 mm (-2.320 in. to 526.97 in.) @ longitudinal velocity in steel |
0 to 90 in 0.1 increments |
2 fully independent gates for amplitude and TOF measurements |
Variable over entire displayed range |
Variable from Gate Start to end of displayed range |
Variable from 2 to 95% full screen height |
Positive and Negative Threshold, Minimum Depth (Gate 1 and Gate 2) |
5 locations available (manual or auto selection) |
Thickness, Soundpath, Projection, Depth, Amplitude, Time-Of-Flight, Min./Max. Depth, Min./Max. Amplitude |
Standard Gate 2-Gate 1, Optional IF Gate Tracking |
Overshoot (dB) value for DGS/AVG, ERS (equivalent reflector size) for DGS/AVG, AWS D1.1/D1.5 A, B, C and D values, Reject Value, Echo to RefdB values |
Standard |
Up to 50 points, 110 dB dynamic range |
Custom DAC (up to 6 curves), 20-80% View |
Standard OD or Bar correction for Angle Beam measurements |
Zero-cross measurement algorithm, V-Path correction, Single or Echo-to-Echo, Encoded B-scan |
Package Includes:
– EPOCH 650 Digital ultrasonic flaw detector
– AC or battery operation
– Charger/AC adapter (100 VAC, 115 VAC, 230 VAC, 50 Hz or 60 Hz)
– Rechargeable lithium-ion battery
– Transport case
– USB cable
– Quick reference card
– Comprehensive operation manual (CD)
Additional information
Brand | Olympus |
---|